Book
Book your appontment now, for a time that works best for you.
Repair
We'll diagnose and explan the issue, and repair the appliance.
Relax
Appliance repairs are covered by a 90-day satisfaction guarante.
WHY CHOOSE US?

Our work is hinged on the values of integrity, high quality, and customer satisfaction. Hence, you can never go wrong when choose to use our services!

Honest, high quality work that you can afford. We know how to treat you right, give you exceptional service, and follow through with our promises. Our philosophy has always been to treat everyone like we would want to be treated.

Our mission is to serve our clients and provide them with their appliances repaired in a cost effective fashion. We believe in the importance of well cared for appliances inside the your home setting and are doing our best to make the appliance repair experience fast and friendly.

READY TO BOOK NOW?

APPLIANCE REPAIR NEW YORK

Refrigerator Repair
Oven Repair
Dryer Repair
Washer Repair

Sub-Zero is the embodiment of style and also efficiency refrigeration. It isn’t simply a device, your Sub-Zero is an essential element of your ideal cooking area. It makes sense that you would not wish to trust your refrigerator to just any appliance repair company. You desire a group of Sub-Zero refrigerator repair work professionals that can shield your financial investment while offering the costs service you are entitled to.

It Is Fixed Appliance Repair is the company you need to rely on with every one of your Sub-Zero repair work needs. Our professionals concentrate on Sub-Zero service so you can trust that we have the skills to finish the job right.

HOW TO USAGE THE ERROR CODE TROUBLESHOOTING OVERVIEW

Mistake Codes suggest troubles signed up by particular components. If error codes are registered, they will certainly show up before temperature level analyses while in Diagnostic Mode.

NOTE: If Error Codes appear with a blinking “SOLUTION” annunciator before starting Diagnostic Mode, the device experienced excessive compressor run condition that might or may not be connected with the Error Codes presented

To initiate Diagnostic Setting, press and also hold either COLDER secret, after that press the POWER key, after that release both keys. Currently, check to see if Mistake Codes exist, being sure to toggle through all error and temperature level analyses by pushing either COLDER key or either WARMER key. (See Error Code Table Below).

If Error Codes appear during Diagnostic Setting, follow the Error Code Troubleshooting Overview on the following page. The left column of the troubleshooting guide provides the error codes. The details in the appropriate column discusses what tests to execute and/or what action to take to remedy the error.

NOTE: If mistake codes are observed in diagnostic mode, a non-flashing SERVICE annunciator will show up on the LCD when Diagnostic Setting ends, indicating mistake codes are still saved. Error Codes should be gotten rid of from the digital control memory by hand. To get rid of the non-flashing SERVICE annunciator and the mistake codes, the issue has to be fixed and also the unit should get on, then:.

  • On a model UC-24C: Press the Freezer WARMER as well as COLDER tricks for fifteen (15) seconds.
  • On a version UC-24B, UC-24R, or UC-24RO: Press the Refrigerator WARMER as well as COLDER tricks for fifteen (15) secs.

Error Code Table

CODEINDICATION
05Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
20Defrost under-heat with no voltage feedback through Gray/White wire at defrost start
21Defrost overheat
22No voltage feedback through Gray/White wire at defrost start
23Defrost overheat with no voltage feedback through Gray/White wire at defrost start
24Defrost under-heat
30N/A
40Excessive Freezer Compressor Run
50Excessive Refrigerator Compressor Run
Error CodeCAUSESOLUTION
Error Code 10The refrigerator is too warm and/or the upper cabinet has been open too longYou will receive this error if your refrigerator’s upper cabinet has been open too long or if the upper cabinet is too warm. To resolve the error, disconnect the power from the unit at the circuit breaker. Leave the power off for at least one minute. Turn the power back on and keep the refrigerator door closed until the unit has reached optimal temperature.

Mistake Code 05.
A. If “EE” for refrigerator area was shown as well as “SERVICE” flashing, check the following:.

  1. Thermistor electric connections as well as continuity from thermistor to J5 on control panel. Reconnect/ fixing.
  2. Resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F( 0 ° C). Replace if defective. B. If “EE” for fridge compartment was NOT showed, issue is recurring thermistor mistake:.
  3. Door not shutting correctly. Appropriate door closing trouble.
  4. Check light button, wiring & electrical links. Fixing wiring/ connections or replace button.
  5. Check thermistor electric links and connection at J5 on control board. Reconnect/ repair work.
  6. Inspect resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F (0 ° C). Replace if malfunctioning.
    C. If “EC 05” and also “SOLUTION” were flashing before initiating analysis mode, device also experienced extreme compressor run problem that might or may not be related to the “05” Mistake Code. See Mistake Code 50 Test/Actions.