Book
Book your appontment now, for a time that works best for you.
Repair
We'll diagnose and explan the issue, and repair the appliance.
Relax
Appliance repairs are covered by a 90-day satisfaction guarante.
WHY CHOOSE US?

Our work is hinged on the values of integrity, high quality, and customer satisfaction. Hence, you can never go wrong when choose to use our services!

Honest, high quality work that you can afford. We know how to treat you right, give you exceptional service, and follow through with our promises. Our philosophy has always been to treat everyone like we would want to be treated.

Our mission is to serve our clients and provide them with their appliances repaired in a cost effective fashion. We believe in the importance of well cared for appliances inside the your home setting and are doing our best to make the appliance repair experience fast and friendly.

READY TO BOOK NOW?

APPLIANCE REPAIR NEW YORK

Refrigerator Repair
Oven Repair
Dryer Repair
Washer Repair

Sub-Zero is the epitome of design as well as efficiency refrigeration. It isn’t just a device, your Sub-Zero is an essential element of your best cooking area. It makes good sense that you would not wish to trust your refrigerator to simply any kind of home appliance repair service business. You want a team of Sub-Zero refrigerator repair work professionals that can protect your investment while offering the costs service you deserve.

It Is Fixed Device Repair is the company you should rely on with every one of your Sub-Zero repair needs. Our technicians concentrate on Sub-Zero solution so you can rely on that we have the skills to finish the job right.

HOW TO USE THE ERROR CODE TROUBLESHOOTING GUIDE

Mistake Codes show troubles signed up by details components. If mistake codes are registered, they will show up prior to temperature readings while in Diagnostic Setting.

KEEP IN MIND: If Error Codes appear with a blinking “SERVICE” annunciator prior to starting Diagnostic Mode, the system experienced extreme compressor run condition that may or might not be connected with the Mistake Codes showed

To launch Diagnostic Setting, press and hold either COLDER secret, after that push the POWER secret, after that launch both tricks. Now, inspect to see if Mistake Codes are present, making certain to toggle with all error and temperature readings by pushing either COLDER vital or either WARMER secret. (See Error Code Table Below).

If Error Codes show up during Diagnostic Setting, follow the Mistake Code Troubleshooting Guide on the adhering to web page. The left column of the troubleshooting overview notes the error codes. The information in the appropriate column discusses what examinations to execute and/or what activity to take to remedy the mistake.

NOTE: If error codes are observed in diagnostic setting, a non-flashing SOLUTION annunciator will appear on the LCD when Diagnostic Mode finishes, indicating mistake codes are still kept. Mistake Codes need to be removed from the digital control memory manually. To clear the non-flashing SERVICE annunciator and also the error codes, the trouble must be fixed and the unit must get on, then:.

  • On a design UC-24C: Press the Fridge Freezer WARMER and also COLDER tricks for fifteen (15) secs.
  • On a design UC-24B, UC-24R, or UC-24RO: Press the Refrigerator WARMER and COLDER tricks for fifteen (15) secs.

Error Code Table

CODEINDICATION
05Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
20Defrost under-heat with no voltage feedback through Gray/White wire at defrost start
21Defrost overheat
22No voltage feedback through Gray/White wire at defrost start
23Defrost overheat with no voltage feedback through Gray/White wire at defrost start
24Defrost under-heat
30N/A
40Excessive Freezer Compressor Run
50Excessive Refrigerator Compressor Run
Error CodeCAUSESOLUTION
Error Code 12The refrigerator is too warm and/or the upper cabinet has been open too longYou will receive this error if your refrigerator’s upper cabinet has been open too long or if the upper cabinet is too warm. To resolve the error, disconnect the power from the unit at the circuit breaker. Leave the power off for at least one minute. Turn the power back on and keep the refrigerator door closed until the unit has reached optimal temperature.

Error Code 05.
A. If “EE” for refrigerator compartment was shown as well as “SOLUTION” blinking, check the following:.

  1. Thermistor electrical connections as well as connection from thermistor to J5 on control board. Reconnect/ repair service.
  2. Resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F( 0 ° C). Replace if malfunctioning. B. If “EE” for fridge compartment was NOT presented, trouble is periodic thermistor error:.
  3. Door not shutting correctly. Correct door closing trouble.
  4. Examine light switch, circuitry & electrical connections. Repair electrical wiring/ connections or replace switch.
  5. Check thermistor electrical connections as well as continuity at J5 on control panel. Reconnect/ repair work.
  6. Examine resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F (0 ° C). Replace if faulty.
    C. If “EC 05” as well as “SERVICE” were flashing before initiating diagnostic setting, device likewise experienced excessive compressor run condition that may or might not be connected with the “05” Error Code. See Mistake Code 50 Test/Actions.