Our work is hinged on the values of integrity, high quality, and customer satisfaction. Hence, you can never go wrong when choose to use our services!
Honest, high quality work that you can afford. We know how to treat you right, give you exceptional service, and follow through with our promises. Our philosophy has always been to treat everyone like we would want to be treated.
Our mission is to serve our clients and provide them with their appliances repaired in a cost effective fashion. We believe in the importance of well cared for appliances inside the your home setting and are doing our best to make the appliance repair experience fast and friendly.
Sub-Zero is the embodiment of style and efficiency refrigeration. It isn’t just a device, your Sub-Zero is an essential element of your excellent cooking area. It makes good sense that you wouldn’t intend to trust your refrigerator to just any kind of appliance repair business. You want a group of Sub-Zero refrigerator repair service experts that can shield your investment while giving the costs service you are worthy of.
It Is Fixed Device Fixing is the firm you need to trust with every one of your Sub-Zero repair work needs. Our service technicians specialize in Sub-Zero service so you can rely on that we have the abilities to do the job right.
HOW TO USAGE THE ERROR CODE TROUBLESHOOTING OVERVIEW
Mistake Codes indicate problems registered by details parts. If mistake codes are signed up, they will certainly appear prior to temperature analyses while in Diagnostic Mode.
NOTE: If Error Codes appear with a flashing “SERVICE” annunciator before launching Diagnostic Setting, the unit experienced extreme compressor run problem that may or may not be connected with the Error Codes presented
To start Diagnostic Setting, press as well as hold either COLDER secret, then push the POWER secret, after that launch both secrets. Currently, examine to see if Error Codes exist, being sure to toggle with all error and also temperature level readings by pressing either COLDER crucial or either WARMER trick. (See Error Code Table Below).
If Error Codes show up during Diagnostic Mode, comply with the Error Code Troubleshooting Guide on the adhering to page. The left column of the troubleshooting overview provides the error codes. The info in the right column discusses what examinations to carry out and/or what activity to require to remedy the mistake.
KEEP IN MIND: If error codes are observed in analysis mode, a non-flashing SOLUTION annunciator will show up on the LCD when Diagnostic Mode ends, indicating mistake codes are still saved. Mistake Codes have to be cleared from the electronic control memory by hand. To clear the non-flashing SERVICE annunciator as well as the mistake codes, the trouble needs to be dealt with and the system must be ON, then:.
Error Code Table
CODE | INDICATION |
05 | Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
06 | Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
07 | Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
08 | Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s |
20 | Defrost under-heat with no voltage feedback through Gray/White wire at defrost start |
21 | Defrost overheat |
22 | No voltage feedback through Gray/White wire at defrost start |
23 | Defrost overheat with no voltage feedback through Gray/White wire at defrost start |
24 | Defrost under-heat |
30 | N/A |
40 | Excessive Freezer Compressor Run |
50 | Excessive Refrigerator Compressor Run |
Error Code | CAUSE | SOLUTION |
Error Code 21 | The defrost temperature is too high | This error may indicate that the freezer evaporator is improperly mounted, or there is an issue with the internal wiring. Contact a Sub-Zero Repair specialist for assistance. |
Error Code 05.
A. If “EE” for fridge area was presented and “SERVICE” flashing, inspect the following:.