Book
Book your appontment now, for a time that works best for you.
Repair
We'll diagnose and explan the issue, and repair the appliance.
Relax
Appliance repairs are covered by a 90-day satisfaction guarante.
WHY CHOOSE US?

Our work is hinged on the values of integrity, high quality, and customer satisfaction. Hence, you can never go wrong when choose to use our services!

Honest, high quality work that you can afford. We know how to treat you right, give you exceptional service, and follow through with our promises. Our philosophy has always been to treat everyone like we would want to be treated.

Our mission is to serve our clients and provide them with their appliances repaired in a cost effective fashion. We believe in the importance of well cared for appliances inside the your home setting and are doing our best to make the appliance repair experience fast and friendly.

READY TO BOOK NOW?

APPLIANCE REPAIR NEW YORK

Refrigerator Repair
Oven Repair
Dryer Repair
Washer Repair

Sub-Zero is the embodiment of style and also performance refrigeration. It isn’t simply an appliance, your Sub-Zero is an essential element of your best kitchen area. It makes good sense that you wouldn’t want to trust your refrigerator to just any type of device repair company. You desire a group of Sub-Zero refrigerator repair service specialists that can safeguard your financial investment while offering the costs solution you deserve.

It Is Fixed Device Repair service is the business you must rely on with all of your Sub-Zero fixing needs. Our specialists focus on Sub-Zero solution so you can trust that we have the abilities to do the job right.

HOW TO USE THE MISTAKE CODE TROUBLESHOOTING OVERVIEW

Error Codes indicate issues signed up by details parts. If error codes are signed up, they will appear before temperature analyses while in Diagnostic Mode.

KEEP IN MIND: If Mistake Codes appear with a flashing “SOLUTION” annunciator prior to starting Diagnostic Mode, the device experienced too much compressor run problem that might or might not be related to the Mistake Codes displayed

To start Diagnostic Mode, press and hold either COLDER trick, after that push the POWER trick, then release both secrets. Currently, inspect to see if Mistake Codes exist, making sure to toggle through all mistake and temperature readings by pushing either COLDER crucial or either WARMER trick. (See Error Code Table Below).

If Error Codes show up throughout Diagnostic Mode, comply with the Error Code Troubleshooting Overview on the following page. The left column of the troubleshooting overview details the error codes. The details in the ideal column describes what tests to perform and/or what action to require to deal with the error.

NOTE: If error codes are observed in diagnostic setting, a non-flashing SERVICE annunciator will certainly appear on the LCD when Diagnostic Setting finishes, indicating error codes are still kept. Error Codes need to be gotten rid of from the digital control memory manually. To clear the non-flashing SOLUTION annunciator and the mistake codes, the problem should be remedied and also the system needs to be ON, then:.

  • On a design UC-24C: Press the Fridge Freezer WARMER and also COLDER secrets for fifteen (15) secs.
  • On a design UC-24B, UC-24R, or UC-24RO: Press the Fridge WARMER as well as COLDER secrets for fifteen (15) secs.

Error Code Table

CODEINDICATION
05Refrig. cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
06Refrig. evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
07Freezer cabinet thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
08Freezer evaporator thermistor read open or shorted for 10+ seconds, or repeatedly read erratic temp’s
20Defrost under-heat with no voltage feedback through Gray/White wire at defrost start
21Defrost overheat
22No voltage feedback through Gray/White wire at defrost start
23Defrost overheat with no voltage feedback through Gray/White wire at defrost start
24Defrost under-heat
30N/A
40Excessive Freezer Compressor Run
50Excessive Refrigerator Compressor Run
Error CodeCAUSESOLUTION
Error Code 90 H 84Communication issue with the main board.This error indicates that the main control board needs to be reset or replaced. Disconnect the refrigerator from the power by unplugging it, or turning off power at the circuit board. Wait ten minutes and reconnect the power. If the fault is not resolved, contact a service technician for additional assistance.

Error Code 90 H 84

A. If “EE” for refrigerator area was presented as well as “SOLUTION” flashing, inspect the following:.

  1. Thermistor electrical links as well as continuity from thermistor to J5 on control board. Reconnect/ repair work.
  2. Resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F( 0 ° C). Change if defective. B. If “EE” for refrigerator compartment was NOT presented, trouble is periodic thermistor error:.
  3. Door not closing effectively. Correct door closing trouble.
  4. Examine light button, electrical wiring & electrical links. Repair electrical wiring/ links or change switch.
  5. Inspect thermistor electrical links and connection at J5 on control board. Reconnect/ repair work.
  6. Check resistance of thermistor– 30,000 to 33,000 ohms at 32 ° F (0 ° C). Change if malfunctioning.
    C. If “EC 05” and “SOLUTION” were flashing before starting analysis mode, device likewise experienced extreme compressor run problem that may or may not be associated with the “05” Mistake Code. See Error Code 50 Test/Actions.