Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Info
Service Diagnostics Mode allows you to identify the firmware as well as software application versions, examination standing of “version specific” system elements as well as sensing units, and alter state of elements where applicable (i.e.– compressor on/off, and so on.).
Enabling Service Setting: To make it possible for Solution Setting, press as well as hold the “WARMER” switch while pressing the “COLDER” button 4 times within 5 secs.
After getting in Service Setting, the very first number that you will certainly see suggests the software application model number for the particular system you are servicing. For instance, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the first number you will certainly see is 11. See chart listed below for corresponding model and software program referral.
The second number you will certainly see shows the software application version launch. For instance, if you see 44 on the display panel it shows software variation 4.4.
Diagnostics:
While in Service Setting, press the “SET” switch to step via Tests 0-9. The initial digit of the screen will reveal the examination number. The second digit indicates the current state of each element under examination and also is displayed as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 as well as 1 reveal an open or shorted problem found at the sensor inputs. Tests 2 via 6 allow you to turn loads ON with the “WARMER” switch as well as OFF with the “COLDER” button. Examinations 7 through 9 confirm state change of the door switches and/or magnetic reed sensor. The component tests available are explained in Offered Element Examinations graph.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Water flow is slower than normal | Water pressure is low | Water pressure is low between 35 – 100 pounds per square inch. A minimum pressure of 35 pounds per square inch is recommended for refrigerators with water filters. |
Improper water valve installed. | Check water connection procedure in installation instructions. Self piercing and 3/16” saddle valves cause low water pressure and may clog the line over time.* | |
Copper tubing has kinks | Turn off water supply and remove kinks. If kinks cannot be removed, replace tubing | |
Water filter is clogged or needs to be changed. | Change water filter. |