Viking Refrigerator Diagnostic Info
Service Diagnostics Setting permits you to determine the firmware and also software program versions, examination condition of “model certain” system elements and also sensing units, and change state of elements where appropriate (i.e.– compressor on/off, etc.).
Enabling Solution Setting: To allow Solution Setting, press and hold the “WARMER” button while pressing the “COLDER” button 4 times within five secs.
After getting in Service Mode, the very first number that you will certainly see shows the software version number for the particular unit you are servicing. For instance, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the first number you will see is 11. See graph listed below for matching model and also software program reference.
The 2nd number you will see shows the software application variation launch. As an example, if you see 44 on the display screen panel it indicates software program version 4.4.
Diagnostics:
While in Service Setting, press the “SET” switch to step via Examinations 0-9. The very first figure of the display screen will reveal the test number. The second digit shows the present state of each element under examination as well as is presented as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 and 1 disclose an open or shorted condition detected at the sensing unit inputs. Examinations 2 via 6 allow you to transform lots ON with the “WARMER” switch and also OFF with the “COLDER” switch. Examinations 7 with 9 confirm state modification of the door changes and/or magnetic reed sensor. The part examinations offered are explained in Available Component Tests graph.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
MeatSavor drawer temperature is too warm | Control settings are too low. | See p 5 to properly adjust controls. |