Our work is hinged on the values of integrity, high quality, and customer satisfaction. Hence, you can never go wrong when choose to use our services!
Honest, high quality work that you can afford. We know how to treat you right, give you exceptional service, and follow through with our promises. Our philosophy has always been to treat everyone like we would want to be treated.
Our mission is to serve our clients and provide them with their appliances repaired in a cost effective fashion. We believe in the importance of well cared for appliances inside the your home setting and are doing our best to make the appliance repair experience fast and friendly.
Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Information
Service Diagnostics Mode permits you to recognize the firmware and also software application variations, test status of “design details” system parts and sensors, and change state of parts where suitable (i.e.– compressor on/off, and so on.).
Enabling Service Mode: To allow Solution Mode, press and hold the “WARMER” switch while pressing the “COLDER” button four times within five secs.
After going into Solution Setting, the very first number that you will see indicates the software version number for the particular device you are servicing. For instance, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the initial number you will certainly see is 11. See chart below for corresponding version as well as software program recommendation.
The 2nd number you will see indicates the software variation release. For instance, if you see 44 on the display panel it shows software program version 4.4.
Diagnostics:
While in Service Mode, press the “COLLECTION” switch to step through Tests 0-9. The first figure of the display screen will certainly show the examination number. The 2nd number indicates the existing state of each component under examination as well as is presented as “1” getting on, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 and also 1 disclose an open or shorted condition spotted at the sensor inputs. Examinations 2 through 6 allow you to turn lots ON with the “WARMER” button as well as OFF with the “COLDER” button. Tests 7 via 9 verify state modification of the door changes and/or magnetic reed sensor. The component tests readily available are explained in Readily available Component Tests chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Refrigerator does not operate | Refrigerator is not plugged in | Plug in refrigerator. |
Control is not on Fuse is blown, or circuit breaker needs to be reset | Properly adjust controls Replace blown fuses. Check circuit breaker and reset. | |
Power outage has occurred. | Call local power company to report outage |