Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Refrigerator Diagnostic Details
Solution Diagnostics Setting allows you to determine the firmware as well as software versions, examination status of “version certain” system components and also sensing units, as well as alter state of parts where appropriate (i.e.– compressor on/off, etc.).
Enabling Service Setting: To allow Solution Mode, press as well as hold the “WARMER” switch while pressing the “COLDER” button four times within five seconds.
After getting in Service Mode, the first number that you will certainly see indicates the software program design number for the particular unit you are servicing. For example, if you are servicing a 24 inch wine cellar (DFUW, DUWC, VUWC), the very first number you will certainly see is 11. See graph listed below for matching version and software program reference.
The 2nd number you will certainly see indicates the software program variation launch. As an example, if you see 44 on the screen panel it indicates software program variation 4.4.
Diagnostics:
While in Service Mode, press the “SET” switch to step via Examinations 0-9. The first number of the display will reveal the examination number. The 2nd number suggests the current state of each element under test and is shown as “1” being ON, CLOSED, or SHORTED and also “0” being OFF or OPEN. Examinations 0 and 1 expose an open or shorted problem identified at the sensing unit inputs. Examinations 2 via 6 enable you to transform loads ON with the “WARMER” button and OFF with the “COLDER” switch. Tests 7 with 9 confirm state modification of the door changes and/or magnetic reed sensor. The component tests offered are explained in Offered Part Examinations graph.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Water droplets form inside of refrigerator | Humidity levels are high or door has been opened frequently | Properly adjust controls Reduce time door is open Organize food items efficiently to assure door is open for shortest time. |